RM 1902, EASEY BLDG., 253-261 HENNESSY ROAD, WANCHAI, HONGKONG | jason@hydraulicpumpvalve.com |
Product Details:
Payment & Shipping Terms:
|
High Light: | commercial hydraulic pumps,high pressure hydraulic pump |
---|
Rexroth A2FM 6X Series Axial Piston Fixed Motor
All-purpose high pressure motor
Size 5 … 1000
Nominal pressure up to 400 bar
Maximum pressure up 450 bar
Open and closed circuit
Metric version
Features
Large variety of available nominal sizes allows exact adjustment to the appliSAARion
High power density
Very high total efficiency
High starting efficiency
Working ports SAE flange or thread
Optional with integrated pressure relief valve
Optional with mounted addifitonal valve: counterbalance valve (BVD/BVE), flushingand boost-pressure valve
Bent-axis design
Size | 5 | 10 | 12 | 16 | 23 | 28 | 32 | 107 | 125 | 160 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | |||
Displacement geometric, per revolution |
Vg | cm³ | 4.93 | 10.3 | 12 | 16 | 22.9 | 28.1 | 32 | 106.7 | 125 | 160.4 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | |
Nominal pressure | pnom | bar | 315 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 350 | 350 | 350 | 350 | 350 | |
Maximum pressure | pmax | bar | 350 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 400 | 400 | 400 | 400 | 400 | |
Maximum speed | nnom 1) | rpm | 10000 | 8000 | 8000 | 8000 | 6300 | 6300 | 6300 | 4000 | 4000 | 3600 | 3600 | 2750 | 2700 | 2240 | 2000 | 1600 | 1800 | |
nmax 2) | rpm | 11000 | 8800 | 8800 | 8800 | 6900 | 6900 | 6900 | 4400 | 4400 | 4000 | 4000 | 3000 | |||||||
Inlet flow 3) | at nnom | qV | l/min | 49 | 82 | 96 | 128 | 144 | 177 | 202 | 427 | 500 | 577 | 648 | 550 | 675 | 795 | 1000 | 1136 | 1600 |
Torque 4) | at pnom | M | Nm | 24.7 | 66 | 76 | 102 | 146 | 179 | 204 | 679 | 796 | 1021 | 1146 | 1273 | 1393 | 1978 | 2785 | 3955 | 5570 |
Rotary stiffness | c | kNm/rad | 0.63 | 0.92 | 1.25 | 1.59 | 2.56 | 2.93 | 3.12 | 11.2 | 11.9 | 17.4 | 18.2 | 57.3 | 73.1 | 96.1 | 144 | 270 | 324 | |
Moment of inertia for rotary group | JTW | kg·m² | 0.00006 | 0.0004 | 0.0004 | 0.0004 | 0.0012 | 0.0012 | 0.0012 | 0.0116 | 0.0116 | 0.022 | 0.022 | 0.0353 | 0.061 | 0.102 | 0.178 | 0.55 | 0.55 | |
Maximum angular acceleration | ɑ | rad/s² | 5000 | 5000 | 5000 | 5000 | 6500 | 6500 | 6500 | 4500 | 4500 | 3500 | 3500 | 11000 | 10000 | 8300 | 5500 | 4300 | 4500 | |
Case volume | V | l | 0.17 | 0.17 | 0.17 | 0.2 | 0.2 | 0.2 | 0.8 | 0.8 | 1.1 | 1.1 | 2.7 | 2.5 | 3.5 | 4.2 | 8 | 8 | ||
Weight (approx.) | m | kg | 2.5 | 5.4 | 5.4 | 5.4 | 9.5 | 9.5 | 9.5 | 32 | 32 | 45 | 45 | 66 | 73 | 110 | 155 | 325 | 336 |
Size | 5 | 10 | 12 | 16 | 23 | 28 | 32 | 107 | 125 | 160 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | |||
Displacement geometric, per revolution |
Vg | cm³ | 4.93 | 10.3 | 12 | 16 | 22.9 | 28.1 | 32 | 106.7 | 125 | 160.4 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | |
Nominal pressure | pnom | bar | 315 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 350 | 350 | 350 | 350 | 350 | |
Maximum pressure | pmax | bar | 350 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 400 | 400 | 400 | 400 | 400 | |
Maximum speed | nnom 1) | rpm | 10000 | 8000 | 8000 | 8000 | 6300 | 6300 | 6300 | 4000 | 4000 | 3600 | 3600 | 2750 | 2700 | 2240 | 2000 | 1600 | 1800 | |
nmax 2) | rpm | 11000 | 8800 | 8800 | 8800 | 6900 | 6900 | 6900 | 4400 | 4400 | 4000 | 4000 | 3000 | |||||||
Inlet flow 3) | at nnom | qV | l/min | 49 | 82 | 96 | 128 | 144 | 177 | 202 | 427 | 500 | 577 | 648 | 550 | 675 | 795 | 1000 | 1136 | 1600 |
Torque 4) | at pnom | M | Nm | 24.7 | 66 | 76 | 102 | 146 | 179 | 204 | 679 | 796 | 1021 | 1146 | 1273 | 1393 | 1978 | 2785 | 3955 | 5570 |
Rotary stiffness | c | kNm/rad | 0.63 | 0.92 | 1.25 | 1.59 | 2.56 | 2.93 | 3.12 | 11.2 | 11.9 | 17.4 | 18.2 | 57.3 | 73.1 | 96.1 | 144 | 270 | 324 | |
Moment of inertia for rotary group | JTW | kg·m² | 0.00006 | 0.0004 | 0.0004 | 0.0004 | 0.0012 | 0.0012 | 0.0012 | 0.0116 | 0.0116 | 0.022 | 0.022 | 0.0353 | 0.061 | 0.102 | 0.178 | 0.55 | 0.55 | |
Maximum angular acceleration | ɑ | rad/s² | 5000 | 5000 | 5000 | 5000 | 6500 | 6500 | 6500 | 4500 | 4500 | 3500 | 3500 | 11000 | 10000 | 8300 | 5500 | 4300 | 4500 | |
Case volume | V | l | 0.17 | 0.17 | 0.17 | 0.2 | 0.2 | 0.2 | 0.8 | 0.8 | 1.1 | 1.1 | 2.7 | 2.5 | 3.5 | 4.2 | 8 | 8 | ||
Weight (approx.) | m | kg | 2.5 | 5.4 | 5.4 | 5.4 | 9.5 | 9.5 | 9.5 | 32 | 32 | 45 | 45 | 66 | 73 | 110 | 155 | 325 | 336 |
1) | These values are valid at: - for the optimum viscosity range from vopt = 36 to 16 mm2/s - with hydraulic fluid based on mineral oils |
2) | Intermittent maximum speed: overspeed for unload and overhauling processest, t < 5 s and Δp < 150 bar |
3) | Restriction of input flow with counterbalance valve |
4) | Torque without radial force, with radial force see table "Permissible radial and axial forces of the drive shafts" |
1) | These values are valid at: - for the optimum viscosity range from vopt = 36 to 16 mm2/s - with hydraulic fluid based on mineral oils |
2) | Intermittent maximum speed: overspeed for unload and overhauling processest, t < 5 s and Δp < 150 bar |
3) | Restriction of input flow with counterbalance valve |
4) | Torque without radial force, with radial force see table "Permissible radial and axial forces of the drive shafts" |
R909610413 | A2FM107/61-VPBXX0-S |
R909437964 | A2FM107/61W-PPB026 |
R909434444 | A2FM107/61W-PPB080 |
R909437811 | A2FM107/61W-PZB016 |
R909437060 | A2FM107/61W-PZB026 |
R909422336 | A2FM107/61W-PZB080 |
R909604873 | A2FM107/61W-PZB106 |
R909419471 | A2FM107/61W-PZBXX0-S |
R909424300 | A2FM107/61W-VAB010 |
R902035057 | A2FM107/61W-VAB010D |
R902107801 | A2FM107/61W-VAB010F |
R902138131 | A2FM107/61W-VAB020 |
R902161277 | A2FM107/61W-VAB027 |
R909611129 | A2FM107/61W-VAB027D |
R902090226 | A2FM107/61W-VAB027F |
R909423125 | A2FM107/61W-VAB030 |
R909429526 | A2FM107/61W-VAB040 |
R902006704 | A2FM107/61W-VAB100 |
R902060436 | A2FM107/61W-VAB171 |
R902018169 | A2FM107/61W-VAB181 |
R909610668 | A2FM107/61W-VBB010 |
R902137754 | A2FM107/61W-VPB020 |
R909416550 | A2FM107/61W-VSD510 |
R902137736 | A2FM107/61W-VZB010 |
R902137752 | A2FM107/61W-VZB020 |
R902054530 | A2FM107/61W-VZB181 |
R909448003 | A2FM125/61W-NBB020 |
R909603889 | A2FM125/61W-NBB020D |
R902204891 | A2FM125/61W-PAB010-S |
R909433587 | A2FM125/61W-PAB016 |
R909605547 | A2FM125/61W-PAB016D |
R902047315 | A2FM125/61W-PAB020-S |
R909603477 | A2FM125/61W-PAB026 |
R909604893 | A2FM125/61W-PAB026D |
R909409635 | A2FM125/61W-PAB030 |
R909446368 | A2FM125/61W-PAB037 |
R909421672 | A2FM125/61W-PAB080 |
R909605840 | A2FM125/61W-PAB170D |
R909604597 | A2FM125/61W-PBB027D |
R909423745 | A2FM125/61W-PBB080 |
R909409630 | A2FM125/61W-VAB010 |
R902035060 | A2FM125/61W-VAB010D |
R902138097 | A2FM125/61W-VAB010F |
R902255825 | A2FM125/61W-VAB010V |
R902137680 | A2FM125/61W-VAB020 |
R909605696 | A2FM125/61W-VAB020D |
R902094703 | A2FM125/61W-VAB020F |
R902033431 | A2FM125/61W-VAB020-S |
R902137962 | A2FM125/61W-VAB027 |
R909409636 | A2FM125/61W-VAB040 |
R909438186 | A2FM125/61W-VAB180 |
R909409637 | A2FM125/61W-VBB010 |
R909409638 | A2FM125/61W-VBB020 |
R902042483 | A2FM125/61W-VSD100 |
R909610801 | A2FM125/61W-VZB010 |
A10VSO18 Series Rexroth Hydraulic Pump , Variable Axial Piston Pump
Variable High Pressure Hydraulic Pump A10VSO45 Series With Long Service Life
Quick Speed Rexroth Hydraulic Pump , A10VSO71 Series Variable Piston Hydraulic Pump
Hydac Pressure Filter Element Replacement 0240D 0260D 0280D Series ISO Approved
Pressure Replacement Filter Element Hydac 0800D 0900D 1320D 1500D Series
Hydac 0240R Series Return Line Elements For Hydraulic Return Line Filter
Parker Denison Hydraulic Piston Pumps Variable Volume PVP16 Series
PVP41 Series Parker Denison Hydraulic Pumps Variable Volume Piston Pumps
PV140 PV180 Series Parker Hydraulic Pumps Axial Piston Pump On Hand